Sustainable mobility with renewable hydrogen: a framework for refueling station design and optimisation using liquid organic hydrogen carriers LOHCs Scientific Reports
Want create site? Find Free WordPress Themes and plugins.

Sustainable mobility with renewable hydrogen: a framework for refueling station design and optimisation using liquid organic hydrogen carriers LOHCs Scientific Reports

The performance of the hydrogenation and dehydrogenation reactors is related to mass conversion and yield of hydrogen in a time series. As the hydrogen dispensation systems were the same for all scenarios, they were not considered as part of the analytical framework for technical feasibility and cost analysis. Figure 3 shows a simplified process diagram of the heat pump cycle integrated with a molten salt thermal energy storage tank. The thermal heat is transferred from the thermal energy storage tank through heat exchangers to the dehydrogenation reactor, when it is needed. This is due to the low-capacity factor of the solar-only case, resulting from the intermittency of solar electricity generation, compared to the grid-only case. However, the challenge at this stage is the energy losses, which are output as the energy losses in the form of heat produced in the PEM electrolyser and thermal energy storage tank.

The HPC for the HRS with a hydrogen production capacity of 500 kgH2/day is calculated by It is calculated based on the cost input variables and assumptions summarised in Sect. The procurement cost for equipment is an essential factor that can significantly affect the overall cost estimations. The optimisation was performed in hourly intervals to account for the reaction time of the hydrogenation and dehydrogenation processes. Julia is an open-source programming language that was used in this study for the linear programming (LP)-based optimisation problem for the HRS. The proposed process model considers an HRS with the entire hydrogen supply chain, including hydrogen demand forecast, hydrogen production, hydrogen storage, heat management, and dispensing units as illustrated in Fig.

However, the heat pump consumes only a small portion of the electricity. The amount of waste heat and energy loss generated by the electrolyser accounts for approximately 30% of the total electrolyser energy content. The PEM electrolyser is the main consumer of electricity, followed by the heat pump during the energy consumption stage. 26 shows the flow of solar energy and its transformation across various physical equipment of the HRS. In this study, the Sankey diagrams are used to visualise the energy flows, analyse the use of the electrical energy sources across the HRS, and identify the potential opportunities for energy efficiency improvement. Figure 25 illustrates the energy consumption for different LOHC-based HRS for different scenarios.

This study focuses on the HRS with onsite hydrogen production, hydrogen storage, heat management, and dispensing units, as shown in Fig. Although LOHCs have been considered for storage and transportation of hydrogen in various applications15,16,17,18,19, their applications in HRS have not been widely investigated. In 2018, Chiyoda Corporation in Japan built a pilot plant using SPERA technology for large-scale hydrogenation and dehydrogenation. One key advantage of this process is that the LOHC can be stored and distributed as a liquid at ambient temperature and pressure at both loaded and unloaded conditions.

For solar-only case (Fig. 20 a) the use of the NEC/DNEC pair shows the highest capacity factor of the electrolyser with the lowest solar-electrolyser ratio of 7.69. However, the size of the dehydrogenation reactor is considerably larger for NEC compared to other LOHCs, due to its very high STY of the dehydrogenation. For the solar-only case (Fig. 19a) NEC/DNEC pair requires the smallest size of all equipment, while DBT requires the largest. The HPC and capacity factor are highly dependent on the performance of energy sources. Blue bars indicate the HPC excluding the cost of the hydrogen dispensing unit; orange bars indicate the HPC including the cost of the hydrogen dispensing unit.

The variations in the capital and operating costs of all equipment as illustrated in Fig. The cost of dispensation electricity and dispensing unit remain constant in both scenarios and are not affected by the selection of LOHCs. The cost structure for equipment and electricity exported to grid of different LOHC-based HRS with (a) a solar PV-driven electrolyser and (b) a grid-connected electrolyser, in a unit of A$. The use of the DBT/PDBT pair results in the highest capacity factor of hydrogenation, while using MCH/TOL and DEC/NAP shows the highest capacity factor of dehydrogenation. For grid-only case (Fig. 20b), the electrolyser has a relatively high capacity factor when using either MCH/TOL or NEC/DNEC.

Figure 14 shows the thermal energy storage level for dehydrogenation. There are two main electricity supply sources to be considered, which are a) an onsite solar PV system and b) existing power plants. The variable operating cost is the total electricity cost for optimal scheduling of the HRS, including the electricity consumed by water electrolysis and other system components. The fixed operating cost includes the O&M cost of all equipment except for the solar PV system and PEM electrolyser. The capital and operating more details on this page costs are the largest components of the total annualised cost.

However, the waste heat content in the aggregate is equal in both cases because of the same aggregated amount of hydrogen production. One major difference between the two cases is the relative energy content sizes in the respective equipment, with the solar-only case being larger. Further losses that occurred at the end could be identified as an opportunity to improve energy efficiency and solve the intermittency in renewable electricity supply in the future.

However, the design capacity of the dehydrogenation reactor for NEC/DNEC with a solar PV price of A$2000 is nearly double that of other LOHCs. The design capacity of each piece of equipment is similar for the use of the same LOHC as shown in Fig. The design capacity of the dehydrogenation reactor is more sensitive to the changes in renewable energy prices than other LOHCs when using NEC/DNEC as LOHCs. The cost structure for equipment and electricity exported to the grid of different LOHC-based HRS when the capital costs of a solar PV system are (a) A$2000 (b) A$1500 (c) A$1000 respectively.

Did you find apk for android? You can find new Free Android Games and apps.
Ý kiến bạn đọc